As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ONE BURN MARK BETWEEN FS 409.00 AND 409+16, AT STRINGER 26L. REMOVED BURNED FASTENER FOUND COUNTERSINK DAMAGED STEPPED UP HOLE TO A NR 6 FASTENER HOLE AND ALL DAMAGE IS GONE AFTER CONTER SINK IAW REO 601R-53-00-115, REV C. INSTALLED NEW FASTENER BETWEEN FS 409 AND FS 409+16, AT STGR 26L IAW REO 601R-53-00-115, REV C. CLASSIFIED AS A MAJOR REPAIR.