What was found
TWO BURN MARKS BETWEEN FS 409+128 AND FS 424, BETWEEN STRINGER 27L AND 26L. BLENDED BURNS, REF SRM 51-12-00. BLEND A MEASURES .021" D, .450"L, .600"W. BLEND B MEASURES .015" D, .500"L, .500"W. DAMAGE FOUND TO BE OUT OF LIMITS (NO LIGHTNING STRIKE ALLOWED TO WING SKINS). ROTO-PEENED, RE-WORKED AREA IAW SRM 51-24-11. RESTORED SURFACE FINISH TO RE-WORKED AREA SRM 51-25-01. THIS IS CONSIDERED A MAJOR REPAIR IAW GMM 5-3.