LT LOWER WING PLANK LANDING FOR ACCESS PANEL 550DB HAS AN INDICATION NOTED IN THE AFT OTBD AREA APPROX 12" LONG X .250" X 50 PERCENT FSH, FAILED NDT INSPECTION. REPAIRED IAW REO 601R-57-21-030, REV J.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT LOWER WING PLANK LANDING FOR ACCESS PANEL 550DB HAS AN INDICATION NOTED IN THE AFT OTBD AREA APPROX 12" LONG X .250" X 50 PERCENT FSH, FAILED NDT INSPECTION. REPAIRED IAW REO 601R-57-21-030, REV J.