What was found
PAX DOOR LOWER SILL PROXIMITY SENSOR ANGLE HAS CORROSION ON SEVERAL PLACES. REMOVED ANGLE IAW SRM 51-41-02-001-001-A01. LOCATED, DRILLED & DEBURRED HOLES IN NEW SILL ANGLE ALSO ATTACHED NUT PLATES IAW SRM 51-40-06-001-001-A01, 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-45-00-001-001-A01 DWG SH670-31825, REV A. INSTALLED CAP ANGLE MID STA 330 WITH NEW SERVICEABLE PART IAW SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW ASA SOP 5702.