What was found
PAX DOOR LOWER SILL AFT FLOOR SUPPORT ANGLE HAS CORROSION AROUND FASTENERS AND 1 FASTENER HAS CORRODED AWAY, REMOVED AFT ANGLE THAT WAS FOUND TO BE BEYOND ALLOWABLE LIMITS IAW SRM 51-42-06-001-001-A01. LOCATED AND DRILLED UP NEW SERVICEABLE PART (AFT FLOOR SUPPORT ANGLE) IAW SRM 51-40-11-001-001-A01. INSTALLED NEW SERVICEABLE AFT ANGLE IAW SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01 & DWG SH670-31821. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW ASA SOP 5702.