What was found
GEAR DISAGREE MESSAGE, CLEARED AFTER MANUAL EXTENSION USED, ACFT RETURNED, R & R PSEU IAW AMM 32-61-01, AIPC 32-61-01, FIG 1, ITEM 5. PERFORMED GAP CHECKS OF NOSE GEAR OLEO AND UPLOCK SENSORS IAW AMM 32-61-05. OPS CHECKED GOOD, NO OTHER DEFECTS FOUND. ACFT OK FOR SERVICE PERFORMED FUNCTIONAL TEST OF GEAR EXTENSION/ RETRACTION SYS IAW AMM 32-30-00, OPS CHECKED GOOD.