What was found
CORROSION FOUND ON FWD SIDE OF LT 280 FLOORBEAM, UPPER EDGE, BL 0 TO LBL 10. BLENDED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. INSTALLED NEW FLOORBEAM IAW SRM 51-42-06-001-001-A01 DWG SH670-32153. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FWD SIDE OF LT 280 FLOORBEAM, UPPER EDGE, BL 0 TO LBL 10. BLENDED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. INSTALLED NEW FLOORBEAM IAW SRM 51-42-06-001-001-A01 DWG SH670-32153. MAJOR REPAIR.