What was found
FOUND LOWER SERVICE DOOR SILL ANGLE CORRODED. FOUND TO BE MORE THAN 30 PERCENT OF THE AREA OF THE LENGTH OF ANGLE. FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-21-23-101-002-A01 NOTE 1. REMOVED ANGLE IAW SRM 51-42-06-001-001-A01. LOCATED, DRILLED AND DEBURRED AS REQUIRED ON REPLACEMENT SERVICE ANGLE IAW SRM 51-42-11-001-001 AND DWG SH670-31950. INSTALLEDANGLE, IAW DWG SH670-31950, SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01.