As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PAX DOOR CUTOUT LOWER SILL KICKPLATE ANGLE HAS CORROSION DAMAGE AT FWD END. REMOVED KICKPLATE ANGLE FROM PAX DOOR OBTAINED NEW ANGLE LOCATED DRILL HOLES, DEBURED AS REQUIRED AND INSTALLED NUTPLATES IAW SRM 51-40-11-001-001, 51-45-00-001-001. INSTALLED KICKPLATE ANGLE IAW SRM 51-42-06-001-A01 AND 51-42-21-001-001-A01 AND IAW DWG SH670-31810. MAJOR REPAIR.