What was found
DURING AVDEC INSPECTION, FOUND CORROSION AT PAX DOOR AT BS 349, LBL 35 SILL STRUCTURE. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-42-06-001-001-A01, 51-41-02-001-001-A01, AND DWG SH670-31810.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING AVDEC INSPECTION, FOUND CORROSION AT PAX DOOR AT BS 349, LBL 35 SILL STRUCTURE. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-42-06-001-001-A01, 51-41-02-001-001-A01, AND DWG SH670-31810.