What was found
FRAME 319.70 CORRODED FWD SIDE BETWEEN STR 26RT-26LT. BLENDED OUT CORROSION ON FRAME ATTACH FLANGE AND IN RADIUS IAW SRM 51-21-06-001-001-A01 FRAME OUT OF LIMITS IAW SRM 53-21-06-101-002-A01. BLENDED CORROSION ON FRAME 319.70 BETWEEN STR 27 AND 26L IAW SRM 51-21-06-001-001-A01 OUT OF LIMITS IAW SRM 51-21-06-101-002-A01. REMOVED REMAINDER OF CORROSION FROM FWD SIDE OF FRAME 319.70 BETWEEN STR 26R-26L IAW SRM 51-21-06-001-001-A01.