What was found
BURNED RIVET ON STR 0 BETWEEN FS 280 & 295. INSTALLED FASTENER ON STR 0 BETWEEN FS 280 & 295 IAW SRM 51-42-06-001-001-A01, SUPP 53-00-00 AND REO 670-53-00-045, PT B 06-OCT 14. REMOVED TEMP FASTENER ON STR O BETWEEN FS 280 & 295 IAW SRM 51-42-10-001-001-A01 & SRM SUPP 53-00-00. INSTALLED PERM FASTENER ON STR O BETWEEN FS 280 & 295 IAW SRM 51-21-16-001-001-A01, SUPP 53-00-00 & REO 670-53-00-045.