What was found
FLOORBOARD SUPPORT ANGLE AT FS 280.00 HAS 2 CORRODED HOLES, SCREW HOLES. R & R FLOORBOARD SUPPORT ANGLE WITH NEW SUPPORT ANGLE AT FS 280.00 IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-21-001-001-801 DWG CC670-34256-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBOARD SUPPORT ANGLE AT FS 280.00 HAS 2 CORRODED HOLES, SCREW HOLES. R & R FLOORBOARD SUPPORT ANGLE WITH NEW SUPPORT ANGLE AT FS 280.00 IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-21-001-001-801 DWG CC670-34256-3.