What was found
SERIVCE DOOR SILL ANGLE CORRODED. CORROISON WAS FOUND OUT OF LIMITS IAW SRM 51-21-23-101-002-A01. REMOVED UPPER AND LOWER SILL ANGLES AND CLIP FROM SERVICE DOOR IAW SRM 51-42-00-001-001-A01. LOCATED, DRILLED AND ASSEMBLIED SERVICE DOOR SILL ANGLES AND CLIP IAW SRM 51-42-06-001-001-A01 AND DWG SH690-319.06 AND SH670-31996. INSTALLED SERIVCE DOOR ANGLES AND CLIP IAW SRM 51-42-06-001-001-A01 AND 51-42-20-001-001-A01 AND DWG SH690-31986 AMD SH670-31996.