What was found
FS 549 FRAME ANGLE CORRODED BETWEEN STR 18-19L . REMOVED CORROSION FROM ANGLE IAW SRM 51-21-06-001-001-A01. BLENDED AREA WAS FOUND TO BE WITHIN LIMITS ON SRM 53-31-23-101-001-A01. UPON FURTHER EVALUATION FOUND ADDITIONAL CORROSION ON ANGLE. REMOVED FASTENERS TO FACILITATE CORROSION REMOVAL. REMOVED CORROSION, REF SRM 51-42-06-001-001-A01, 51-42-22-001-001-A01 AND 51-21-06-001-001-A01. MEASURED MECHANICALLY AND FOUND MINIMUM MATERIAL THICKNESS TO BE .044" IS OUT OF LIMITS IAW 53-00-07. COMPLIED WITH EA 32-2015-277, REV DATED 7/8/15, PERMANENT REPAIR. COMPLIED WITH EA 32-2015-277.