What was found
MAIN AVIONICS DOOR SEAL CONTACT SURFACE IS CORRODED. REMOVED CORROSION FROM MAIN ACCESS DOOR SEAL CONTACT SURFACE IAW AMM. NO ALLOWABLE LIMITS PERMITTED IN AREA IAW SRM 53-00-01-101-001-A01. COMPLIED WITH GREO 670-53-21-0241, REV B ONCE ECTC RECEIVED. BLENDED IS WITHIN ALLOWABLE LIMITS IAW REO 670-53-21-242. COMPLIED WITH ECTC ERO 670-53-21-242 AND MODSUM ECTC IS67053210097. COMPLIED WITH ECTC REO 670-53-21-242 AND REO 670-53-21-242, REV B DATED 07/29/201. COMPLIED WITH MODSUM IS6705-3210097, REV A.