Service difficulty report · Door · Cndair CL6002C10

Difficulty date
July 31, 2015
Submitted
August 14, 2015
Operation
Air carrier
Aircraft
N722EV
Make and model
Cndair CL6002C10
Aircraft serial
10127
Aircraft time
28,710 hours, 20,167 cycles
Part
Door
Condition
Out Of Adjust
Location
Rt Emer Exit
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT EMERGENCY EXIT FAILED FUNCTION CHECK TOOK 60LBS TO OPEN. ADJUSTED THE STEP FIT STOP SCREWS IAW 52-21-00-820-801. ADJUSTED RT OVERWING PROX SENSOR BRACKET AT TOP OF DOOR EMERGENCY EXIT PUSH PULL TEST WITHIN LIMITS FUNCTIONAL CHECK GOOD IAW AMM 52-21-00-720-801-A01. OPS CHECK GOOD ON RT WING EMERGENCY EXIT IAW AMM 52-21-00-710-801-A01. REBONDED STRIKER PLATE ON RT EMERGENCY DOOR PROXIMITY LEVER IAW AMM 51-31-00-992-801-A01.