What was found
FOUND CRACK IN LAN, SILL OF LT FWD EQUIPMENT COMPARTMENT. REMOVED DISCREPANT LANDING IAW SRM 51-42-06-001-001-A01 AND SRM 51-42-13-001-001-A01. LOCATED FASTENER HOLES IN SERVICABLE BAY DOOR LANDING, RT SIDE AND INSTALLED ALL SOLID FASTENERS AFT OF FS 173.00. REF SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01 QWL CC670-33040. INSTALLED ALL FASTENERS COMMON TO SKIN PANEL AND DOOR LANDING IAW STS EA 32-2015-356. INSTALLED, 2EA, RIVETS THRU FS 173 FRAMED CLEAT/CLIP ON DOOR LANDING & FLOOR WEB, IAW SRM 51-42-06-001-001-A01. COMPLIED WITH ECTC EA 32-2015-356.