Service difficulty report · Overheat Loop · Cndair CL6002C10

Difficulty date
August 30, 2015
Submitted
September 3, 2015
Operation
Air carrier
Aircraft
N712EV
Make and model
Cndair CL6002C10
Aircraft serial
10074
Aircraft time
30,876 hours, 21,645 cycles
Part
Overheat Loop
Condition
Shorted
Location
Mlg
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MLG OVERHEAT WARNING AFTER TAKE OFF. DECLARED AN EMERGENCY AND COMPLIED WITH QRH AND LANDED AT 66.7K LBS. ACFT RETURNED TO DEPARTURE AFTER T/O. EMERGENCY DECLARED AS A PRECAUTION. UPON FURTHER INSPECTION, FOUND RT ELEMENT TO HAVE LOW RESISTANCE FROM INNER TO OUTER PORTIONS OF ELEMENT. R & R IAW AMM 26-14-04. ALL CHECKS GOOD AT THIS TIME.