What was found
BURN ON SKIN BETWEEN BS 295- 310 AND STIRNGERS 25-26R. DRILLED THROUGH BURN IN SKIN USING .0128" DRILL BIT AND DEBURRED NEW HOLE IN SKIN. WORK DONE REF SRM 53-00-00, TR 53-0050. PERFORMED ET INSPECTION OF THE REWORKED AREA IAW NDTM 51-20-006. NO CRACKS NOTED. PERFORMED ET CONDUCTIVITY INSPECTION OF THE REWORKED AREA IAW NDTM 53-00-000-252-A01. MEASURED CONDUCTIVITY IS 34 PERCENT IACS AT 60HZ. INSTALLED SOLID FASTENER AND WASHER IN NEW HOLE IAW SRM 53-00-00, TR 53-0050, THIS IS A PERMANENT REPAIR.