What was found
CORROSION ON STRINGER 26R BETWEEN FS 319.7 - 349. BLENDED DAMAGE BETWEEN FS 319 & FS 349 FOUND DEEP PITTING TO BE OUT OF LIMITS REF SRM 53-21-03-101-002-A01. REMOVED CLEATS AT FS 319, FS 333, FS 349 IAW SRM 51-42-0-001-001-A01. REMOVED STRINGER CLEATS ON THE FWD AND AFT FACE OF FRAME 295. REMOVED STRINGR FROM FS 280- FS 349, REMOVED 42 EA RIVETS AT DS 295 TO 349 TO FOM, IAW SRM 51-42-06-001-001-A01. DRILLED UP NEW STG 26R FWD AND AFT PIECES FROM FS 280-364 AND SPLICE ANGLE REF SRM 51-40-11-001-001-A01. INSTALLED STR 26R BETWEEN FS 280 AND FS 364 AND INSTALLED STR SPLICE AT FS 333 IAW SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-0A01 IAW DWG SH670-31630 AND SH670-32420. COMPLETED INSTALLATION OF INTERCOSTAL BETWEEN FS 349-FS 364 AND CLEATS IAW SRM 51-42-06-001-001-A01.