What was found
INTERCOSTAL CORRODED AT STR 20 RT, BETWEEN FRAMES 349.00-364.00. DAMAGE EXCEEDS THE ALLOWABLE LIMITS OF SRM 53-21-23-101-002-A01. REMOVED INTERCOSTAL, SR20R, FS 349-TS394 IAW SRM 51-42-06-001-001-A01, 51-42-21-000-001-A01. INSTALLED INTERCOSTAL AND ANGLE AT FS 349-364, STR 20 RT IAW DWG SH670-31994 AND SRM 51-42-06-001-001-A01. LOCATED AND DRILLED NEW SERVICEABLE DOOR SURROUND INTERCOSTAL SH 670-31994-1 IAW DWG SH670-31994 AND SRM 51-40-11-001-001-A01. LOCATED AND INSTALLED NEW SERVICEABLE CLEAT AT FS 364, STR 20R IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, DWG SH 670-31950.