What was found
SERVICE DOOR THRESHOLD HAS CORROSION DAMAGE. LOCATED FASTENERS HOLES IN SERVICABLE MOUNTING ANGLE IAW SRM 51-42-06-00-001-001-A01 AND DWG SH670-31980, SRM 51-40-11-001-001-A01. INSTALLED THE LOWER MOUNTING ANGLE ON SERVICE DOOR SILL IAW SRM 51-42-06-001-001-A01, 51-42-+21-001-001-A01 AND DWG SH6470-31950. SEALED SERVICE DOOR MOUNTING ANGLE, RESTORED FINISH AND APPLIED CIC AS REQUIRED IAW SRM, REV 51-0056, 51-21-11-001-001-A01, 51-21-16-001-001-A01.