As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AT SERVICE DOOR ON UPPER FLOOR SUPPORT. REMOVED AND DRILLED UP NEW UPPER FLOOR SUPPORT AT SERVICE DOOR IAW SRM 51-42-06-001-001-A01 AND 51-40-11-001-001-A01. INSTALLED NEW UPPER FLOOR SUPPORT ANGLE ON LOWER SILL ANGLE IAW SRM 51-42-06-001-001-A01 AND DWG SH670-39150, SRM 51-42-21-001-001-A01.