What was found
SERVICE DOOR HAS 3 ATTACH ANGLES CORRODED. REMOVED AND DRILLED UP 4 EA NEW ATTACH ANGLES AT SERVICE DOOR IAW SRM 51-42-06-001-001, A01 AND 51-40-11-001-001, A01. ON FURTHER INSPECTION, FOUND 4 EA ATTACH ANGLES THAT WERE CORRODED. INSTALLED THE 4 EA ATTACH ANGLES, LOWER SILL ANGLES TO THE SILL STRUCTURE IAW SRM 51-42-06-001-001, A01 AND DWG SH670-31950. ATTACHED THE 4 EA ATTACH ANGLES TO THE FLOOR PROTECTOR ANGLES IAW SRM 51-42-06-001-001, A01, DWG SH670-31950. RESTORED FINISH, SEALED ATTACH ANGLES AS REQUIRED IAW SRM TEMP REV 51-0056, 51-21-16-001-001, A01 AND APPLIED CIC IAW SRM 51-21-11-001-001, A01.