What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK ON RIGHT ELEVATOR SPAR AT ES 76-75. STOP DRILLED CRACK AND INSTALLED REPAIR ANGLES AT ES 76-75 IAW EO 12-5520-29-B1092, DC9 SRM 51-20, 51-30-02, 51-20-03, AND 55-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK ON RIGHT ELEVATOR SPAR AT ES 76-75. STOP DRILLED CRACK AND INSTALLED REPAIR ANGLES AT ES 76-75 IAW EO 12-5520-29-B1092, DC9 SRM 51-20, 51-30-02, 51-20-03, AND 55-02.