What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND SUB FLOORBOARD AT BS 160 TO 200 OUTBOARD RIGHT HAND TOP SIDE CORRODED. MECHANICALLY REMOVED CORROSION, FABRICATED, TRIMMED, DRILLED, DEBURRED, COUNTERSUNK PANEL, TREATED, PRIMED AND INSTALLED HAT SECTION IAW B737 SRM 51-10-3, 53-22-0 FIG 3 AND 53-01 FIG 1.