What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE CABIN FLOOR PANEL NR 29 AT BS 236-308 RBL 1-24 CORRODED ON MOST OF FACE AND SPOTS ON BACKSIDE OF HAT SECTION REINFORCEMENTS. CUT OUT NEW SKIN AND HAT REINFORCEMENT SECTIONS. DRILL, TRIMMED, ASSEMBLED, TREATED, PRIMED, INSTALLED NEW INSULATION AND EDGE STRIPS IAW DC9 SRM 51-10-3, 51-30-2, 51-70-0 AND 53-21-0.