What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD CARGO DOOR STOPS CHAFED AND CORRODED. REMOVED AND REPLACED 10 NEW PADS IAW DC9 SRM 51-30-2 AND OHM 52-30-1 PG 57.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD CARGO DOOR STOPS CHAFED AND CORRODED. REMOVED AND REPLACED 10 NEW PADS IAW DC9 SRM 51-30-2 AND OHM 52-30-1 PG 57.