What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND WEB ON CUSP LINE AT BS 218L CRACKED AND CORRODED. FABRICATED REPAIR DOUBLER IAW DC9 SRM 51-10-3, 51-30-1 AND 53-20-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND WEB ON CUSP LINE AT BS 218L CRACKED AND CORRODED. FABRICATED REPAIR DOUBLER IAW DC9 SRM 51-10-3, 51-30-1 AND 53-20-1.