What was found
DURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND CORROSION ON HORIZONTAL STABILIZER TAKEOFF WARNING MECHANISM AT BS 351 L20R. REMOVED AND REPLACED MANUAL OVERRIDE CONTROL BELLCRANK SHAFT, INTERCONNECT BRACKET, P/N 5915830-501, LIMIT SWITCH CONTROL ARM, P/N 4915833-1, IAW DC9 M/M 27-40-5, 27-40-0.