What was found
FOUND CUSP WEB AT BS 256 AND L18L CORRODED AT INTERSECTION OF SUBFLOOR AND SIDEWALL PANELS. REMOVED CORRODED AREA OF CUSP WEB AND REMOVED FRAME-TO-CUSP FITTING. FABRICATED REPAIR DOUBLER FOR CUSP WEB. REPLACED FRAME-TO-CUSP FITTING. INSTALLED REPAIR DOUBLER AND FRAME-TO-CUSP FITTING IAW DC9 SRM 51-10-3, 51-10-4, 51-30 AND MM 53-20-1.