What was found
FOUND FORWARD FLOOR SUPPORT AT BS 200 AND RBL 24 TO RBL 42 CORRODED. REMOVED CORRODED FLOOR SUPPORT. FABRICATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 53-01 FIG 1, 51-30-3, 51-10-2 AND 53-11-1 FIG 13.