What was found
FOUND FORWARD FLOOR SUPPORT AT BS 165-200 AND LBL 44 CORRODED. REMOVED CORRODED FLOOR SUPPORT, FABRICATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-2, 51-10-3 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FORWARD FLOOR SUPPORT AT BS 165-200 AND LBL 44 CORRODED. REMOVED CORRODED FLOOR SUPPORT, FABRICATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-2, 51-10-3 AND 51-30-5.