What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, FOUND FRAME AT BS 617 RIGHT TO HAVE TEMPORARY REPAIR. REMOVED AND REPLACED FRAME AT BS 617 RIGHT IAW DC9 SRM 51-30-02 AND 51-30-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, FOUND FRAME AT BS 617 RIGHT TO HAVE TEMPORARY REPAIR. REMOVED AND REPLACED FRAME AT BS 617 RIGHT IAW DC9 SRM 51-30-02 AND 51-30-05.