What was found
(AUS) FORWARD PRESSURE BULKHEAD WEB FORWARD FACE CRACKED IN THE FOLLOWING AREAS:- 1. THREE CRACKS LOCATED AT RBL 5.7 UNDER RADAR SCANNING SUPPORT BRACKETS - CRACK LENGTHS 15MM (0.59IN), 20MM (0.787IN) AND 24MM (0.944IN) 2. ONE CRACK LOCATED AT LBL 5.7 UNDER RADAR SCANNING SUPPORT BRACKETS - CRACK LENGTH 23MM (0.905IN) 3. ONE CRACK RUNNING VERTICALLY ADJACENT TO BLO JUST ABOVE WL 1845 - CRACK LENGTH 18MM (0.708IN) FOUND DURING ULTRASONIC AND EDDY CURRENT INSPECTIONS IAW ER