What was found
DURING C-17 CHECK A 1/2 INCH CRACK WAS FOUND ON AFT CARGO DOOR LOWER CROSS BEAM AT FASTENER HOLE AFT END OF DOOR BS 801.5, STR 23 RT. MAINTENANCE CUTOUT DAMAGED AREA OF CROSS BEAM AT BS 801.5, STR 23 RT; FABRICATED A REPLACEMENT SECTION OF TEE CHORD, 2 EACH REPAIR ANGLES, AND 2 EACH RADIUS FILLERS; INSTALLED REPAIR PARTS IAW E.O. 52-33-02, FIG. 5, PG. 29-34.