What was found
DURING C-18 CHECK INTERGRANULAR CORROSION WAS FOUND ON RT HORIZONTAL STABILIZER FORWARD CLEVIS, AT FORWARD LOWER FACE BS 1088, WL 256, RBL 30. MAINTENANCE REMOVED BUSHING FROM RT HORIZONTAL STABILIZER FORWARD CLEVIS; OVERSIZED CENTER SECTION CLEVIS FORWARD LOWER HOLE; FABRICATED A NEW REPLACEMENT BUSHING IAW B737-300 SRM 55-10-10, PG. 112; INSTALLED REPAIR PART IAW AWA E.R. 03-5512-04044-TB1.