Service difficulty report · Selector Valve · Airbus A319132

Difficulty date
March 3, 2004
Submitted
March 4, 2004
Operation
Air carrier
Aircraft
N820AW
Make and model
Airbus A319132
Aircraft serial
1397
Aircraft time
11,741 hours, 4,456 cycles
Part
Selector Valve
Part number
114079017
Part serial
CWDDDH8498
Condition
Failed
Location
Zone 140
Part time
16,439 hours, 6,897 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PHX - AIR TURNBACK - FLT 0251 - AFTER TAKEOFF FROM PHX EN ROUTE TO MSP RECEIVED ECAM MESSAGE LG LGCIU 2 FAULT, TURNED BACK TO PHX AND LANDED WITHOUT FURTHER EVENT. MAINTENANCE REMOVED AND REPLACED LANDING GEAR CONTROL AND INTERFACE FACE UNIT (LGCIU) NR 2 (5GA2) IAW AMM 32-31-71. AIRMAN INDICATED A HARD FAULT FOR LANDING GEAR SELECTOR VALVE (40GA). REMOVED AND REPLACED LANDING GEAR SELECTOR VALVE IAW AMM 32-31-12. JACKED AIRCRAFT AND PERFORMED LANDING GEAR OPERATIONAL CHECK, CHECK WAS GOOD.