What was found
DURING C-18 CHECK A 2 INCH CRACK WAS FOUND IN RT SHEAR WEB FORWARD OF FRAME AT BS 580, STR 17. RT MAINTENANCE CUTOUT DAMAGE ON RT SHEAR WEB FROM BS 578 TO BS 597, STR 17 RT; FABRICATED A FILLER AND REPAIR ANGLE; INSTALLED REPAIR PARTS IAW SRM 51-70-13, FIG. 1.