What was found
MCN - DURING C19 CHECK DISCOVERED LEVEL 2 GALVANIC CORROSION FOUND ON FLOOR SUPPORT LOCATED FROM BS 1011 TO BS 1015, WL 208, AND BL 7L. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW BOEING 737-300 SRM 53-60-51-1A-1 FIG 101. MAINTENANCE REMOVED AND INSTALLED NEW FLOOR SUPPORT FROM BS 1011 TO BS 1015, WL 208 AND BL 7L IAW BOEING 737-300 SRM 51-40-02-0G FIG 12.