As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING POST FLIGHT INSPECTION DISCOVERED A 6 INCH PIECE OF ALUMINUM STICKING UP FROM TRAILING EDGE OF LT ELEVATOR. TEMP REPAIR WAS PERFORMED AND AIRCRAFT WENT ON A ONE-TIME FERRY FLIGHT FOR PERMANENT REPAIR. MAINTENANCE REPAIRED LT ELEVATOR BY REMOVING CONDUCTIVE FRAME AND FABRICATING NEW FRAME MFG DWG 183N2006. INSTALLED FRAME AND FASTENERS THROUGH OUT SKIN IAW MFG DWG 183N2006.