MCN - DURING C24 CHECK DISCOVERED CRACK, 1.1 INCHES LONG, ON THE R1 DOOR LOWER FORWARD TORQUE BOX FLOOR WEB ATTACH ANGLE AT BS 298, WL 208 AND BL 53R. MAINTENANCE REMOVED, FABRICATED AND INSTALLED REPLACEMENT WEB ATTACH ANGLE AT BS 298, WL 208 AND BL 53R IAW BOEING 737-300 SRM 51-40-02-0G FIGURES 8, 12, AND 13.