What was found
PHX - DURING C4 INSPECTION, FOUND CORROSION ON LEFT AFT LAVATORY THRESHOLD SUPPORT 'I' BEAM AT STATION 1006 AND STATION 1016. REMOVED AND REPLACED DAMAGED AREA PER SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING C4 INSPECTION, FOUND CORROSION ON LEFT AFT LAVATORY THRESHOLD SUPPORT 'I' BEAM AT STATION 1006 AND STATION 1016. REMOVED AND REPLACED DAMAGED AREA PER SRM 51-40-02. (M)