What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER FLOORBEAM T CAP STATION 947.5 LBL 9 TO RBL 9. REPAIRED PER SRM 51-10-02, 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER FLOORBEAM T CAP STATION 947.5 LBL 9 TO RBL 9. REPAIRED PER SRM 51-10-02, 51-20-01.