As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK ON AFT LWR CORNER OF R-1 DOOR FROM RADIUS OF CUTOUT TO FASTENER HOLE. REAMED HOLE .025 AND PLUGGED IAW 51-10-02. FABRICATED REPAIR DOUBLERS PER SRM 51-30-01. FABRICATED FILLERS PER SRM 53-10-01. TREATED AND PRIMED IAW SRM 51-20-01 AND INSTALLED DOUBLERS 2024T3 .063 QQA 250/5 R687660 FILLERS 2024T3 .025 QQA 250/5 R706895.