What was found
MAIN ENTRY DOOR IS NOT CLOSING CORRECTLY (STOPS 12 INCHES TO 16 INCHES SHORT OF NORMAL WHEN BEING CLOSED WITH THE AUXILIARY HYDRAULIC PUMP). RESOLUTION: INSPECTED AND FOUND MAIN ENTRY DOOR ACTUATOR ATTACH BRACKET( PN 1159BM50216-1), INTERCOSTAL (PN 159B10456-23) AND ANGLES (PN 159B10055-21 AND 159B10055-19) CRACKED/BROKEN. REPLACED THE ACTUATOR ATTACH BRACKET AND INTERCOSTAL WITH NEW UNITS. SPLICED IN NEW SEGMENTS OF ANGLES AND INSTALLED NEW SPLICE ANGLES (PN SE35101132-19 AND SE35101132-21). ALL WORK COMPLETED IAW MFG REPAIR DWG SE35101132. (K)