As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED INSPECTION THE RIGHT HAND MAIN LANDING GEAR FORWARD SIDE-BRACE BEARING HOUSING WAS FOUND GOUGED ON THE INNER SURFACE. MAINTENANCE ACCOMPLISHED A BLEND OUT REPAIR IAW EMB GST-113/02. THE DYE PENETRANT INSPECTION WAS SATISFACTORY AFTER REPAIR. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.