What was found
CENTER OMEGA BEAM HAS CORROSION IN RADIUS AT FR 20. CENTER OMEGA BEAM WAS REPAIRED IAW SRM 53-21-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER OMEGA BEAM HAS CORROSION IN RADIUS AT FR 20. CENTER OMEGA BEAM WAS REPAIRED IAW SRM 53-21-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.