What was found
FLT 3190 - CREW REPORTED THAT ON ATTEMPTED ENG START, THE RT STARTER/GEN CONTINUED TO RUN WITH THE ENG SHUT DOWN AND THE STARTER SW OFF. THE CREW RECEIVED A FIRE IND AND ACTIVATED THE FIRE EXTINGUISHER. MX INSPECTED THE A/C AND REMOVED AND REPLACED THE RIGHT STARTER/GEN IAW B1900D MM 24-30-01, THE RIGHT ENG POWER SUPPLY AND THE BUS TIE CONTROL PC BOARD WERE ALSO REPLACED IAW B1900D MM 24-30-00. THE RIGHT FIRE BOTTLE WAS REPLACED IAW B1900 MM 24-30-00. AIRCRAFT RELEASED FOR SERVICE. (M)